闺蜜男友猛撞H花液H深,欧美高清性色生活片免费观看 ,精品久久久久久亚洲综合网,亚洲天天做日日做天天爽

     
  中文版 English
 
Hot news:
  Products
IEC Test Finger Probe
IPX1-IPX9K Waterproof Test Equipment
Electrical Appliance Testing Equipment
Environmental Test Chamber
Battery test equipment
Textile Test Equipment
Mechanical testing machine
Plug and socket testing equipment
test package
Laser Power Senser Measurement
Soil Sensor
Hot Product
IPX1 IPX2 Drip Waterproof Test...
UL1439 Sharp Edge Tester
BND-TPK05 IEC 60529 Test Probe...
IEC62368 test probe kit BND-TP...
IEC 61032 Standard Test Probe ...
IEC60320 EN60320 Appliances co...
UL 498 Standard Plugs and Rece...
IPX1 to IPX4 Drip rain test an...
Vertical horizontal vibration ...
IP5X IP6X Sand and dust proof ...
climate constant temperature a...
IPX1 to IPX9 waterproof testin...
 
 
Products
Xenon lamp aging test machine
Name:Xenon lamp aging test machine
Type:BND-HXD-800L
Manufacturer:The xenon lamp aging tester uses a xenon arc lamp that mimics the full sunlight spectrum to reproduce the destructive light waves that exist in different environments, and can provide the appropriate environmental simulation and accelerated testing for scientific research, product development and quality control.
Product Description:

1 Summer

1.1 Equipment name

Xenon lamp aging tester

1.2 Equipment model

BND-HXD-800L

1.4 Specimen limitation

Do not use explosive substances, combustible substances, or materials containing such substances as specimens. Otherwise, there is a risk of explosion, fire, or other accidents.

●Do not allow corrosive substances to enter the tank. Use of corrosive substances or humidified water, especially stainless steel, resin, silicon, etc., may cause a significant decrease in the corrosion resistance of the product.

●Do not use living organisms or substances that will exceed the permissible heat generation as specimens.

1.5 Equipment use

The xenon lamp aging tester uses a xenon arc lamp that mimics the full sunlight spectrum to reproduce the destructive light waves that exist in different environments, and can provide the appropriate environmental simulation and accelerated testing for scientific research, product development and quality control. It can be used for the selection of new materials, the improvement of existing materials or the evaluation of changes in durability after changes in the composition of materials, can be a good simulation of the changes in different environmental conditions, materials exposed to sunlight.

1.7 Standard

GB/T16422.2 Plastics Laboratory light exposure test method part 340, ASTM G155 part and other standards!

2 size specification

2.1 Inner box size

W800*H800*D800mm (drum diameter 500mm sample fixture width 75*height 150*thickness 5mm can put about 40)

2.2 Outer case size

W1350*H2050*D1850mm subject to the object.

2.3 Sample condition

Sample placement test space is not more than three quarters of the total space, no heat load.

3 Equipment Performance

3.1 Temperature range inside the box

0℃80℃

3.2 Blackboard temperature range

+45℃100℃(±3℃)Depending on the temperature inside the box and the irradiation intensity settings

3.3 Box temperature deviation

±2℃(without light on)

3.4 Temperature resolution

0.1°C

3.5 Temperature Fluctuation

±0.5℃(without light)

3.6 Relative humidity range

20% to 95% R.H (Controlled range chart in purple area below)

3.7 Relative humidity deviation

±3%R.H (without light)

3.8 Relative humidity fluctuation

±2.5%R.H (without light)

3.9 Light source type

Domestic 1 water-cooled xenon lamp wavelength 280-800nm, power 4.5KW, average service life of 1200 hours, equipped with a set of light monitoring and feedback sensors, does not contain a filter. (The equipment comes with lamp cooling circulating water)

3.10 Irradiation intensity

@340nm irradiation intensity 0.35 ~ 0.6W/m2 adjustable

3.11Rotation speed

1-9RPM

3.12 Rain function

Support internal and external spray, can be indirect spray, continuous spray.

3.13 Function Mode

Irradiation mode, dark mode, spray mode can be alternately cycle operation.

※The above performance was measured under the conditions of ambient temperature 25℃±3℃, relative humidity ≤85% unloaded without specimen.

4 structural characteristic

4.1 Controller characteristics

(1) Hardware architecture: PLC listed Xindjie XD5 series + MCGS 7-inch human-machine interface touch screen

(2) Software developed independently by BONAD (expandable and powerful, can be customised according to the requirements of non-standard change software)

(3) Flat design, easy to operate.

4.2 Control mode

●Programmes: 50 groups of programmes, each group of programmes has 50 segments, you can set all cycles of the programme, part of the cycle, programme connection, set the end-of-programme action, set the standby action.

●Determined value: running time and running conditions can be set.

4.3 Sensors

PT100 3-wire high accuracy sensor

4.4 Analogue output

Voltage pulse (SSR) 2 points, DC 24V, minimum pulse width 5ms.

4.5 Communication interface

●USB: The controller can download historical curves and historical data, historical data is saved in Excel format, you can download the required data by date. Historical data is saved in JPG image format, which can be enlarged, reduced and then downloaded as required.

●RS485 interface

5 safety device

5.1 Electrical control system

●Heating and humidification over-temperature protection ●Overload short circuit leakage protection ●Blower over-current protection ●Lamp over-temperature protection

●Water shortage protection ●Power shortage reverse phase protection ●Shower pump overcurrent protection

5.2 Refrigeration system

●Compressor overcurrent protection ●Compressor overpressure protection ●Compressor overtemperature protection

6 Environmental conditions of use

6.1 Equipment placement

No strong vibration around the equipment

No strong electromagnetic field influence around the equipment

No flammable, explosive, corrosive substances and dust around the equipment.

Appropriate space for use and maintenance around the equipment, as shown in the figure below:

A: not less than 10cm

B: not less than 60cm

CNot less than 60cm

D: not less than 150cm

6.2 Environmental conditions

Temperature: +5℃30℃ Relative humidity: ≤85% Barometric pressure: 86kPa106kPa

6.3 Power supply

Voltage: AC380V±10%, frequency: 50HZ, protective earth ground resistance less than 4Ω.

Users in the installation site for the equipment configuration of the corresponding capacity of the air or power switch, and this switch must be independent for the use of this equipment (not connected to the socket use)

Installed power: 18KW Maximum current: 27A

6.4 Water

Pure or distilled water, not unfiltered tap water;

 